Plumbing Advice

Water Pressure

0.1 Bar
  • Suitable for gravity fed systems if the cold water tank is at least 1 metre above the water outlet. If under 1 metre a pump will be required.
  • Suitable for combi boilers
  • Suitable for megaflow systems
0.2 Bar
  • Suitable for gravity fed systems if the cold water tank is at least 2 metres above the water outlet. If under 2 metres a pump will be required.
1.0 - 1.5 Bar
  • Not suitable for gravity fed systems unless a pump is used.
  • Suitable for most combi boilers – please check pressure output with a plumber to confirm.
  • Suitable for megaflow systems
1.5 - 2.0 Bar
  • Not suitable for gravity fed systems unless a pump is used.
  • Not suitable for most combi boilers – please check pressure output with a plumber to confirm.
  • Suitable for megaflow systems
2.0 Bar+
  • Not suitable for gravity fed systems unless a pump is used.
  • Not suitable for combi boilers.
  • Suitable for most megaflow systems – please check pressure output with a plumber to confirm.

Water Systems

Gravity Fed Systems
  • Cold water header tank usually situated in the loft, sometimes situated directly above the hot water cylinder.
  • Hot water cylinder.
Combi Boilers
  • Single gas heated unit that heats water as it passes through.
  • No hot water cylinder
  • No cold water header tank.
Megaflow System
  • Large hot water cylinder under pressure from the mains water supply.
  • No cold water header tank.

Showers

Exposed Shower
  • Pipe work is buried in the wall (in some cases on the surface).
  • Shower valve is mounted on the surface.
  • Used for mounting on solid walls.
Built in Shower
  • Pipe work is buried in the wall.
  • Shower valve is buried in the wall.
  • Used for mounting on stud walls.
Thermostatic Shower
  • Runs off hot and cold water feeds.
  • Temperature is kept constant even if the flow of water changes.
Manual Shower
  • Runs off hot and cold water feeds.
  • Temperature fluctuates if the flow of water changes.
Digital Shower
  • Same function as a thermostatic shower.
  • Shower controlled by remote digital panel.
  • Valve contained in box mounted in a loft space / airing cupboard / under bath or other suitable area.
  • Some include pumps for a boost on gravity fed water systems.
Electric Shower
  • Runs directly off mains cold water feed.
  • Heats the water as it passes through.
  • Requires separate fuse / trip switch.
  • For low mains water pressure pumped electric showers are available which will run off the cold water storage tank.

Lighting

Zone 0 (min IPx7)
  • Water tight fitting.
  • Suitable for underwater lighting.
  • All fittings must be SELV (Max 12v).
Zone 1 (min IPx4)
  • Jet proof.
  • Suitable for inside shower enclosures / over baths.
  • Up to 2.25m above the bath or shower tray.
Zone 2 (min IPx4)
  • Splash proof.
  • Suitable for around wet areas where fitting may get splashed.
  • Up to 0.6m outside zone 1.
Other Areas
  • Where fittings won’t come into contact with water.

IP Ratings

IP (Ingress Protection) rating.

First Digit - Foreign Bodies Second Digit - Liquids
0 No protection 0 No protection
1
  • Protected against solid objects greater than
  • 50mm (e.g. accidental touch by hands)
1
  • Protection against vertically falling drops of
  • water (e.g. condensation)
2
  • Protected against solid objects up to
  • 12mm (e.g. fingers)
2
  • Protection against direct sprays of water up
  • to 15 degrees from vertical
3
  • Protected against solid objects greater than
  • 2.5mm (e.g. tools and wires)
3
  • Protection against direct sprays of water up
  • to 60 degrees from vertical
4
  • Protected against solid objects greater than
  • 1mm (e.g. small tools and wires)
4
  • Protection against water sprayed from all
  • directions – limited ingress permitted
5
  • Protected against dust, limited ingress (e.g.
  • no harmful deposit)
5
  • Protected against low pressure jets of water
  • from all directions – limited ingress permitted
6
  • Totally protected against dust
6
  • Protected against high pressure jets of water
  • (use on ship deck) – limited ingress permitted
7
  • Protected against the effects of immersion
  • between 15cm and 1m
8
  • Protected against long periods of immersion
  • under pressure

Please note this section is intended as a guide only. We recommend getting advice from a qualified fitter before purchasing any plumbing or electrical goods. We will not be held liable for any issues caused by use of this guide.